2660 EGLINTON AVE W
ApprovedLast refreshed on Oct 6, 2026
- Permit number
- 16 252979 ALT
- Permit type
- AS Alternative Solution
- Applied
- 2016-11-18
- Issued
- Not available
Actions
Exact address alerts may depend on monitor support.
Timeline
Applied
2016-11-18
Issued
Not available
Completed
2017-11-06
Project description
Proposed design of the service rooms at rapid transit stations does not comply with the applicable egress requirements. The alternative approach to compliance for service rooms and suites is base on the provision of these being normally unoccupied and controlled access for authorized staff, fire separation of not less than 1-hour fire-resistance rating from adjacent floor areas, provision for audible and visual notification devices for emergency notification, separate fire alarm zoning for the west service suites at concourse and platform level, and timed egress analysis for extended length of travel requirements.
Permit fields
- City area grid code
- W0532
- Postal code
- M6M
- Record created
- 2026-10-06T21:31:25.5786+00:00
- Revision
- 0
- Street name
- EGLINTON
- Street number
- 2660
- Street type
- AVE
- street_direction
- W
- Work
- Alternative Solution
- Street (from open data)
- 2660 EGLINTON AVE
Not a municipal ward number.