2109 FINCH AVE W

Approved

Last refreshed on Oct 6, 2026

Permit number
21 137930 ALT
Permit type
AS Alternative Solution
Applied
2021-04-09
Issued
Not available

Actions

Create monitor from this address

Exact address alerts may depend on monitor support.

Report data issueOpens your email app with this record prefilled.

Timeline

  1. Applied

    2021-04-09

  2. Issued

    Not available

  3. Completed

    2021-05-25

Project description

Water closets in barrier free washrooms are with a water tank. The water closets are the elongated type, needed to facilitate user needs for the building. The water closet is 833mm high measured from the finished floor level to the top of the water tank. The OBC requires the grab bar installed behind the water closet to be located within 840mm to 920mm above the finished floor, and 150mm above the water tank. In installing the grab bar at 150mm above the water tank, the height of the grab bar will be at 983mm above the floor, exceeding the OBC height restriction by approximately 63mm. It is proposed to follow provisions in the NBC 2015 and the CSA B651-18 in mounting the grab bar at 100mm above the water tank, which will place the grab bar at 933mm above the finished floor.

Permit fields

City area grid code
W0729
Record created
2026-10-06T21:39:44.042241+00:00
Revision
0
Street name
FINCH
Street number
2109
Street type
AVE
street_direction
W
Work
Alternative Solution
Street (from open data)
2109 FINCH AVE

Not a municipal ward number.

Building permits come from City public data. Confirm on the City site when it matters.