2300 YONGE ST
ApprovedLast refreshed on Nov 15, 2026
- Permit number
- 23 105647 ALT
- Permit type
- AS Alternative Solution
- Applied
- 2023-01-20
- Issued
- Not available
Actions
Exact address alerts may depend on monitor support.
Timeline
Applied
2023-01-20
Issued
Not available
Completed
2023-02-27
Project description
Alternative Solution to address the proposed stairway interconnected floor space between Levels 21-23 which does not comply with OBC 3.2.8.2.(5). Proposed openings are more than 10 m2 in area.It is proposed to provide an interconnected floor space between Levels 21 through 23 of the existing 2300 Yonge Street building despite the entire building not currently being protected by a sprinkler system. Levels 21 through 23 which are undergoing renovation for a new office suite will be sprinklered as part of the renovation, except for a portion of Level 21 which is a separate tenant suite. The existing office suite will be separated from the new interconnected floor space by a 2 hour fire separation and from the corridor by a 1 hour fire separation. The floor opening will be in a separate fire compartment from the existing unsprinklered office suite. See Figure 1 below for reference for the configuration of Level 21.
Permit fields
- Builder
- GREENFERD CONSTRUCTION
- City area code
- N0833
- Postal code
- M4P
- Record created
- 2026-10-06T21:42:54.590229+00:00
- Revision
- 0
- Street name
- YONGE
- Street number
- 2300
- Street type
- ST
- Work
- Alternative Solution
- Street (from open data)
- 2300 YONGE ST
Not a municipal ward number.