Skip to main content
CivicBeam

4610 FINCH AVE E

Cancelled

Last refreshed on Oct 6, 2026

Permit number
24 140244 ALT
Permit type
AS Alternative Solution
Applied
2024-04-24
Issued
Not available

Actions

Create monitor from this address

Exact address alerts may depend on monitor support.

Report data issueOpens your email app with this record prefilled.

Timeline

  1. Applied

    2024-04-24

  2. Issued

    Not available

  3. Completed

    2024-05-07

Project description

The major occupancy in the building is Group B, Division 2, Care and Treatment occupany (LTC) along with Group D, Business and Personal Services. The subsidiary occupancies include Group A, Division 2, Assembly, Group D, Business and Personal Services, Group C, Residential (family suite at Level 2 for short term stays) and Group F, Division 3, Low Hazard Industrial.With a Group B, Division 2 occupancy, it is proposed to construct the building to the requirements in OBC 3.2.2.42A. for a Group C, up to 12 Storeys, Maximum Building Area of 6000 m2, Sprinklered, Encapsulated Mass Timber Construction (EMTC). A building constructed to meet OBC 3.2.2.42A. is limited to a height of not more than 42 m as measured between the floor of the first storey and the uppermost floor level. The building area is not more than 6,000 m2 (currently 3,894 m2). However, the height of the building measured from the floor of the first storey to the floor of the uppermost storey is more than 42 m (currently 46 m).The mass timber will be fully encapsulated with no exposed mass timber in any of the resident sleeping compartments throughout the building. Approximately 33 m2 of exposed CLT is proposed within the Family room and Sunroom (located across the elevator banks on typical levels 4 - 12 of the building). It is also proposed that one column within the Family room will be fully exposed.Levels 1 - 3 will be non-combustible construction, Level 4 will be a combination of non-combustible construction and EMTC (start of EMTC beams and columns and floor slab above). Elevator shafts and exit stairs will be non-combustible construction throughout the height of the building. Levels 5 - 12 will be EMTC construction with concrete core and Level 13/roof (MPH Level) will be constructed with steel and metal deck with concrete core, Level 13 roof will be EMTC.

Permit fields

City area grid code
E2322
Postal code
M1S
Record created
2026-10-06T21:44:36.339051+00:00
Revision
0
Street name
FINCH
Street number
4610
Street type
AVE
street_direction
E
Work
Alternative Solution
Street (from open data)
4610 FINCH AVE

Not a municipal ward number.

Building permits come from City public data. Confirm on the City site when it matters.

open.toronto.ca ↗