553 VAUGHAN RD
ApprovedLast refreshed on Oct 6, 2026
- Permit number
- 26 101904 ALT
- Permit type
- AS Alternative Solution
- Applied
- 2026-01-07
- Issued
- Not available
Actions
Exact address alerts may depend on monitor support.
Timeline
Applied
2026-01-07
Issued
Not available
Completed
2026-02-11
Project description
PROPOSED ALTERNATIVE SOLUTION - ISSUE 1 In lieu of a parapet, two layers of 15.9 mm (5/8 in.) Type X gypsum board will be installed at the second-floor ceiling below the attic space, providing approximately 1 hours of fire-resistance. This enhanced fire-rated ceiling will significantly restrict fire spread into the attic and across the roof plane, achieving the intent of the Code.PROPOSED ALTERNATIVE SOLUTION - ISSUE 2 To maintain the intent of a non-combustible fire separation, a continuous layer of 15.9 mm (5/8 in.) Type X gypsum board will be installed over the party wall at all floor levels. In addition, all floor assemblies will be constructed as 2-hour fire-rated assemblies in accordance with M503. These measures provide equivalent fire performance by protecting the embedded wood joists and limiting fire spread through the party wall.
Permit fields
- City area grid code
- S1222
- Postal code
- M6C
- Record created
- 2026-10-06T21:47:28.357085+00:00
- Revision
- 0
- Street name
- VAUGHAN
- Street number
- 553
- Street type
- RD
- Work
- Alternative Solution
- Street (from open data)
- 553 VAUGHAN RD
Not a municipal ward number.